1500° Series FRT Technical Datasheet


PRODUCT:
1500° SERIES FRT CLASS “A” FIRE RETARDANT “INTUMESCENT” VARNISH OVERCOAT FOR 1500° SERIES FR

PRODUCT DESCRIPTION:
1500° Series FRT Overcoat has been tested and rated by the Underwriters’ laboratories, as an overcoat for 1500° Series FRV Class “A” Fire Retardant “Intumescent” Varnish. 1500° Series FRT is available in three distinctive sheens, i.e. low, semi, or hi-gloss. The use of 1500° Series FRT, as a topcoat over 1500° Series FRV, greatly improves the durability, and cleansibility of 1500° Series FRV. We recommend that 1500° Series FRT be used over 1500° Series FRV, on all surfaces that will be subjected to washing, handling, or where a low, semi, or hi-gloss finish is desired.

SURFACE PREPARATION:
After the application of 1500° Series FRV Class “A” Fire Retardant “Intumescent” Varnish has been completed, allow the surface to dry a minimum of 48 hours. Remove all dust, dirt and foreign matter, from the surface, before applying 1500° Series FRT Overcoat.

APPLICATION:
1500° Series FRT Overcoat can be applied by brush, roller, or spray. Stir the material well before using, then apply a uniform coat at a coverage rate up to 600 to 800 sq.ft./U.S. gallon [44.2 m2/L]. In hard use areas, or where excessive wear is expected, a second coat is suggested. Allow at least 24 hours drying time between coats.

THINNERS:
For thinning and cleaning equipment, use only Mineral Spirits or Flame Control No. 167 Reducer.

WARNING!
Adequate ventilation must be provided during and after application, until the coating has dried. Avoid breathing vapors or spray mist. Consult product MSDS and label before opening container.

PRECAUTIONS:
CAUTION! The liquid coating contains volatile (combustible) solvents. Due care must be exercised during and after application until coating is dry.

PACKAGING:
Standard packaging, 1 gallon, 5 gallon, and 55 gallon containers.

FIRE TESTS:
Flame Spread Rating: Class “A”. When tested as a topcoat over 1500° Series FRV, and tested in accordance with ASTM E-84 (NFPA255), the coating obtained the following fire hazard classification. A complete report from the UNDERWRITERS’ LABORATORIES is available upon request.

FIRE HAZARD CLASSIFICATION
When Applied to Douglas Fir
Coating System Details Flame
Spread
Smoke
Developed
Fuel
Contributed
Type 6 [sealer] applied in one coat at
400 sq.ft./US gal. [9.8 m2/L]
1500° Series FRV [base coat] applied
in two coats at 300 sq.ft./US gal. per coat [7.4 m2/L]
1500° Series FRT [top coat] applied
in one coat at 1800 sq.ft./US gal.
[44.2 m2/L] 15 30-50 10


KEEP OUT OF REACH OF CHILDREN
READ MSDS BEFORE OPENING CONTAINERS


All specifications and suggestions appearing on our labels and in our literature concerning the use of our products are based upon tests and data believed to be reliable. Since the actual use by others is beyond our control, no guarantee, expressed or implied, is made by New York Fire-Shield as to the effects of such use or the results to be obtained.